Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 20 de 478
Filtrar
1.
Artigo em Inglês | MEDLINE | ID: mdl-38625446

RESUMO

PURPOSE: The quality and bias of annotations by annotators (e.g., radiologists) affect the performance changes in computer-aided detection (CAD) software using machine learning. We hypothesized that the difference in the years of experience in image interpretation among radiologists contributes to annotation variability. In this study, we focused on how the performance of CAD software changes with retraining by incorporating cases annotated by radiologists with varying experience. METHODS: We used two types of CAD software for lung nodule detection in chest computed tomography images and cerebral aneurysm detection in magnetic resonance angiography images. Twelve radiologists with different years of experience independently annotated the lesions, and the performance changes were investigated by repeating the retraining of the CAD software twice, with the addition of cases annotated by each radiologist. Additionally, we investigated the effects of retraining using integrated annotations from multiple radiologists. RESULTS: The performance of the CAD software after retraining differed among annotating radiologists. In some cases, the performance was degraded compared to that of the initial software. Retraining using integrated annotations showed different performance trends depending on the target CAD software, notably in cerebral aneurysm detection, where the performance decreased compared to using annotations from a single radiologist. CONCLUSIONS: Although the performance of the CAD software after retraining varied among the annotating radiologists, no direct correlation with their experience was found. The performance trends differed according to the type of CAD software used when integrated annotations from multiple radiologists were used.

2.
Emerg Radiol ; 2024 Apr 18.
Artigo em Inglês | MEDLINE | ID: mdl-38632154

RESUMO

PURPOSE: To investigate the effects of mid-inspiratory respiration commands and other factors on transient interruption of contrast (TIC) incidence on CT pulmonary angiography. METHODS: In this retrospective study, 824 patients (mean age, 66.1 ± 15.3 years; 342 males) who had undergone CT pulmonary angiography between January 2021 and February 2023 were included. Among them, 545 and 279 patients were scanned at end- and mid-inspiratory levels, respectively. By placing a circular region of interest, CT attenuation of the main pulmonary artery (CTMPA) was recorded. Associations between several factors, including patient age, body weight, sex, respiratory command vs. TIC and severe TIC incidence (defined as CTMPA < 200 and 150 HU, respectively), were assessed using logistic regression analyses with stepwise regression selection based on Akaike's information criterion. RESULTS: Mid-inspiratory respiration command, in addition to patient age and lighter body weight, had negative association with the incidence of TIC. Only patient age, lighter body weight, female sex, and larger cardiothoracic ratio were negatively associated with severe TIC incidence. Mid-inspiratory respiration commands helped reduce TIC incidence among patients aged < 65 years (p = 0.039) and those with body weight ≥ 75 kg (p = 0.005) who were at high TIC risk. CONCLUSION: Changing the respiratory command from end- to mid-inspiratory levels, as well as patient age and body weight, was significantly associated with TIC incidence.

3.
Schizophrenia (Heidelb) ; 10(1): 32, 2024 Mar 12.
Artigo em Inglês | MEDLINE | ID: mdl-38472253

RESUMO

The gamma-band auditory steady-state response (ASSR), primarily generated from the auditory cortex, has received substantial attention as a potential brain marker indicating the pathophysiology of schizophrenia. Previous studies have shown reduced gamma-band ASSR in patients with schizophrenia and demonstrated correlations with impaired neurocognition and psychosocial functioning. Recent studies in clinical and healthy populations have suggested that the neural substrates of reduced gamma-band ASSR may be distributed throughout the cortices surrounding the auditory cortex, especially in the right hemisphere. This study aimed to investigate associations between the gamma-band ASSR and white matter alterations in the bundles broadly connecting the right frontal, parietal and occipital cortices to clarify the networks underlying reduced gamma-band ASSR in patients with schizophrenia. We measured the 40 Hz ASSR using electroencephalography and diffusion tensor imaging in 42 patients with schizophrenia and 22 healthy comparison subjects. The results showed that the gamma-band ASSR was positively correlated with fractional anisotropy (an index of white matter integrity) in the regions connecting the right frontal, parietal and occipital cortices in healthy subjects (ß = 0.41, corrected p = 0.075, uncorrected p = 0.038) but not in patients with schizophrenia (ß = 0.17, corrected p = 0.46, uncorrected p = 0.23). These findings support our hypothesis that the generation of gamma-band ASSR is supported by white matter bundles that broadly connect the cortices and that these relationships may be disrupted in schizophrenia. Our study may help characterize and interpret reduced gamma-band ASSR as a useful brain marker of schizophrenia.

4.
J Imaging Inform Med ; 2024 Mar 06.
Artigo em Inglês | MEDLINE | ID: mdl-38448759

RESUMO

This study aimed to investigate the effects of intravenous injection of iodine contrast agent on the tracheal diameter and lung volume. In this retrospective study, a total of 221 patients (71.1 ± 12.4 years, 174 males) who underwent vascular dynamic CT examination including chest were included. Unenhanced, arterial phase, and delayed-phase images were scanned. The tracheal luminal diameters at the level of the thoracic inlet and both lung volumes were evaluated by a radiologist using a commercial software, which allows automatic airway and lung segmentation. The tracheal diameter and both lung volumes were compared between the unenhanced vs. arterial and delayed phase using a paired t-test. The Bonferroni correction was performed for multiple group comparisons. The tracheal diameter in the arterial phase (18.6 ± 2.4 mm) was statistically significantly smaller than those in the unenhanced CT (19.1 ± 2.5 mm) (p < 0.001). No statistically significant difference was found in the tracheal diameter between the delayed phase (19.0 ± 2.4 mm) and unenhanced CT (p = 0.077). Both lung volumes in the arterial phase were 4131 ± 1051 mL which was significantly smaller than those in the unenhanced CT (4332 ± 1076 mL) (p < 0.001). No statistically significant difference was found in both lung volumes between the delayed phase (4284 ± 1054 mL) and unenhanced CT (p = 0.068). In conclusion, intravenous infusion of iodine contrast agent transiently decreased the tracheal diameter and both lung volumes.

5.
Neuroradiology ; 2024 Mar 22.
Artigo em Inglês | MEDLINE | ID: mdl-38514472

RESUMO

PURPOSE: We investigated whether the quality of high-resolution computed tomography (CT) images of the temporal bone improves with deep learning reconstruction (DLR) compared with hybrid iterative reconstruction (HIR). METHODS: This retrospective study enrolled 36 patients (15 men, 21 women; age, 53.9 ± 19.5 years) who had undergone high-resolution CT of the temporal bone. Axial and coronal images were reconstructed using DLR, HIR, and filtered back projection (FBP). In qualitative image analyses, two radiologists independently compared the DLR and HIR images with FBP in terms of depiction of structures, image noise, and overall quality, using a 5-point scale (5 = better than FBP, 1 = poorer than FBP) to evaluate image quality. The other two radiologists placed regions of interest on the tympanic cavity and measured the standard deviation of CT attenuation (i.e., quantitative image noise). Scores from the qualitative and quantitative analyses of the DLR and HIR images were compared using, respectively, the Wilcoxon signed-rank test and the paired t-test. RESULTS: Qualitative and quantitative image noise was significantly reduced in DLR images compared with HIR images (all comparisons, p ≤ 0.016). Depiction of the otic capsule, auditory ossicles, and tympanic membrane was significantly improved in DLR images compared with HIR images (both readers, p ≤ 0.003). Overall image quality was significantly superior in DLR images compared with HIR images (both readers, p < 0.001). CONCLUSION: Compared with HIR, DLR provided significantly better-quality high-resolution CT images of the temporal bone.

6.
JMIR Med Educ ; 10: e54393, 2024 Mar 12.
Artigo em Inglês | MEDLINE | ID: mdl-38470459

RESUMO

BACKGROUND: Previous research applying large language models (LLMs) to medicine was focused on text-based information. Recently, multimodal variants of LLMs acquired the capability of recognizing images. OBJECTIVE: We aim to evaluate the image recognition capability of generative pretrained transformer (GPT)-4V, a recent multimodal LLM developed by OpenAI, in the medical field by testing how visual information affects its performance to answer questions in the 117th Japanese National Medical Licensing Examination. METHODS: We focused on 108 questions that had 1 or more images as part of a question and presented GPT-4V with the same questions under two conditions: (1) with both the question text and associated images and (2) with the question text only. We then compared the difference in accuracy between the 2 conditions using the exact McNemar test. RESULTS: Among the 108 questions with images, GPT-4V's accuracy was 68% (73/108) when presented with images and 72% (78/108) when presented without images (P=.36). For the 2 question categories, clinical and general, the accuracies with and those without images were 71% (70/98) versus 78% (76/98; P=.21) and 30% (3/10) versus 20% (2/10; P≥.99), respectively. CONCLUSIONS: The additional information from the images did not significantly improve the performance of GPT-4V in the Japanese National Medical Licensing Examination.


Assuntos
Licenciamento , Medicina , Japão , Idioma
7.
Br J Radiol ; 97(1154): 462-468, 2024 Feb 02.
Artigo em Inglês | MEDLINE | ID: mdl-38308036

RESUMO

OBJECTIVES: To determine the image characteristics associated with low 18F-FDG (18F-fluorodeoxyglucose) avidity among 8-15 mm solid lung cancer. METHODS: Patients satisfying the following criteria were included: underwent surgery between January 2014 and December 2019 for lung cancer, presented 8-15 mm nodule without measurable ground glass component on preoperative CT, and underwent 18F-FDG PET before resection. Image characteristics, including air bronchogram, concave shape, pleural attachment, and background emphysema, were evaluated by two board-certified radiologists. The Mann-Whitney U test was used to compare maximum standardized uptake (SUVmax) values from 18F-FDG PET images. RESULTS: The analysis included 235 patients. The SUVmax values of lesions with air bronchogram and concave shape were significantly lower than the SUVmax values of lesions without these features (median: 1.55 vs 2.56 and 1.66 vs 2.45, both P < .001), whereas lesions arising from emphysematous lungs had significantly higher SUVmax values than lesions arising from non-emphysematous lungs (2.90 vs 1.69, P < .001). No significant differences were detected between lesions attached and not attached to pleura. The interobserver agreement was almost perfect for air bronchograms and background emphysema (κ = 0.882 and 0.927, respectively), and 89.7% of lesions with air bronchograms and arising from non-emphysematous lungs showed SUVmax values below 2.5. CONCLUSIONS: Among 8-15 mm solid lung cancer, the presence of air bronchograms and concave shape and the absence of background emphysema were associated with low 18F-FDG accumulation. ADVANCES IN KNOWLEDGE: 18F-FDG PET can be misleading in differentiating certain type of small solid lung cancer.


Assuntos
Enfisema , Neoplasias Pulmonares , Humanos , Fluordesoxiglucose F18 , Neoplasias Pulmonares/diagnóstico por imagem , Neoplasias Pulmonares/patologia , Compostos Radiofarmacêuticos , Tomografia por Emissão de Pósitrons/métodos , Tomografia Computadorizada por Raios X/métodos , Pulmão/diagnóstico por imagem , Pulmão/patologia , Tomografia por Emissão de Pósitrons combinada à Tomografia Computadorizada/métodos
8.
Cureus ; 16(2): e54583, 2024 Feb.
Artigo em Inglês | MEDLINE | ID: mdl-38384867

RESUMO

Chronic lung allograft dysfunction (CLAD) continues to be the leading cause of death in the long term after lung transplantation (LTx). CLAD has the following two main subtypes: bronchiolitis obliterans syndrome (BOS) and restrictive allograft syndrome (RAS). BOS features obstructive lung dysfunction, while RAS features restrictive lung dysfunction. Overall, RAS has a worse prognosis. The pathophysiology of CLAD is not fully understood; however, pulmonary infections can trigger CLAD, including coronavirus disease 2019 (COVID-19) pneumonia. Here, we describe a case of a 55-year-old female who received LTx about seven years ago and developed RAS after COVID-19 pneumonia. RAS was ultimately diagnosed based on the clinical course and imaging findings. Steroid pulse therapy and empirical antimicrobial therapy were initiated, but respiratory failure progressed, and the patient died 139 days after COVID-19 diagnosis, and 83 days after dyspnea progression. Clinicians should be aware of unusual stair-step clinical courses and imaging features in a given setting of pulmonary infection including COVID-19 to suspect CLAD in lung transplant patients.

9.
Cureus ; 16(1): e52231, 2024 Jan.
Artigo em Inglês | MEDLINE | ID: mdl-38352095

RESUMO

PURPOSE: The central venous port (CVP) is widely used for intravenous chemotherapy (IVC) in adult patients because of its lower infection rates and easier management than that of a central venous catheter. However, the feasibility and safety of the CVP for IVC in infants remain unknown. This study evaluated the usefulness of CVP for IVC in infants with retinoblastoma. METHODS: The usefulness of CVP was retrospectively evaluated using technical success rates, the safety of CVP placement, and postoperative procedure-related complications in 18 infants with retinoblastoma. This study was conducted at the National Cancer Center Hospital, Chuo-Ku, Tokyo, Japan. RESULTS: The technical success rate was 100% (18/18) without any procedure-related complications. The sum duration of CVP implantation was 12,836 days (mean: 713 ± 453 days, range: 10-1,639 days). Postoperative complications were observed in two cases; one was a port reversal after 20 days, which was reversed by incisional surgery, and another was a catheter-related bloodstream infection after eight days, resulting in CVP removal. The total incidence of CVP-related infections was 5.6% (1/18) and 0.08/1000 catheter days. No other CVP-related complications were noted. CONCLUSION: The use of the CVP for IVC in infants with retinoblastoma was feasible with few complications.

10.
Magn Reson Med Sci ; 2024 Feb 07.
Artigo em Inglês | MEDLINE | ID: mdl-38325833

RESUMO

PURPOSE: The purpose of this study was to investigate the longitudinal MRI characteristic of COVID-19-vaccination-related axillary lymphadenopathy by evaluating the size, T2-weighted signal intensity, and apparent diffusion coefficient (ADC) values. METHODS: COVID-19-vaccination-related axillary lymphadenopathy was observed in 90 of 433 health screening program participants on the chest region of whole-body axial MRIs in 2021, as reported in our previous study. Follow-up MRI was performed at an interval of approximately 1 year after the second vaccination dose from 2022 to 2023. The diameter, signal intensity on T2-weighted images, and ADC of the largest enlarged lymph nodes were measured on chest MRI. The values were compared between the post-vaccination MRI and the follow-up MRI, and statistically analyzed. RESULTS: Out of the 90 participants who had enlarged lymph nodes of 5 mm or larger in short axis after the second vaccination dose, 76 participants (45 men and 31 women, mean age: 61 years) were enrolled in the present study. The median short- and long-axis diameter of the enlarged lymph nodes was 7 mm and 9 mm for post-vaccination MRI and 4 mm and 6 mm for follow-up MRI, respectively. The median signal intensity relative to the muscle on T2-weighted images decreased (5.1 for the initial post-vaccination MRI and 3.6 for the follow-up MRI, P < .0001). The ADC values did not show a notable change and remained in a normal range. CONCLUSION: The enlarged axillary lymph nodes decreased both in size and in signal intensity on T2-weighted images of follow-up MRI. The ADC remained unchanged. Our findings may provide important information to establish evidence-based guidelines for conducting proper assessment and management of post-vaccination lymphadenopathy.

11.
J Neurol Sci ; 457: 122894, 2024 Feb 15.
Artigo em Inglês | MEDLINE | ID: mdl-38266517

RESUMO

BACKGROUND: The influence of limbic-predominant age-related TAR DNA-binding protein of 43 kDa encephalopathy neuropathological change (LATE-NC) on structural alterations in argyrophilic grain disease (AGD) have not been documented. This study aimed to investigate the morphological impact of LATE-NC on AGD through voxel-based morphometry (VBM) technique. MATERIALS AND METHODS: Fifteen individuals with pathologically verified AGD, comprising 6 with LATE-NC (comorbid AGD [cAGD]) and 9 without LATE-NC (pure AGD [pAGD]), along with 10 healthy controls (HC) were enrolled. Whole-brain 3D-T1-weighted images were captured and preprocessed utilizing the Computational Anatomy Toolbox 12. VBM was employed to compare gray matter volume among (i) pAGD and HC, (ii) cAGD and HC, and (iii) pAGD and cAGD. RESULTS: In comparison to HC, the pAGD group exhibited slightly asymmetric gray matter volume loss, particularly in the ambient gyrus, amygdala, hippocampus, anterior cingulate gyrus, and insula. Alternatively, the cAGD group exhibited greater gray matter volume loss, with a predominant focus on the inferolateral regions encompassing the ambient gyrus, amygdala, hippocampus, and the inferior temporal area, including the anterior temporal pole. The atrophy of the bilateral anterior temporal pole and right inferior temporal gyrus persisted when contrasting the pAGD and cAGD groups. CONCLUSION: Comorbidity with LATE-NC is linked to different atrophic distribution, particularly affecting the inferolateral regions in AGD. Consequently, the consideration of comorbid LATE-NC is crucial in individuals with AGD exhibiting more widespread temporal atrophy.


Assuntos
Demência , Doenças Neurodegenerativas , Proteinopatias TDP-43 , Humanos , Atrofia/patologia , Encéfalo/diagnóstico por imagem , Encéfalo/patologia , Demência/patologia , Substância Cinzenta/diagnóstico por imagem , Substância Cinzenta/patologia , Imageamento por Ressonância Magnética/métodos , Doenças Neurodegenerativas/patologia , Proteinopatias TDP-43/patologia
12.
Transplant Proc ; 56(1): 125-134, 2024.
Artigo em Inglês | MEDLINE | ID: mdl-38177046

RESUMO

BACKGROUND: Living-donor liver transplantation (LDLT) is established as a standard therapy for end-stage liver disease; however, vessel reconstruction is more demanding due to the short length and small size of the available structures compared with deceased-donor whole liver transplantation. Interventional radiology (IR) has become the first-line treatment for vascular complications after LDLT. Hepatic venous outflow obstruction (HVOO) is a life-threatening complication after LDLT. The aim of this study of 592 adult-to-adult LDLT cases was to investigate the safety and efficacy of stent implantation for HVOO after LDLT. METHODS: Records of patients who developed HVOO requiring any treatment were collected with special reference to the metallic stent implantation. There were 232 left-side grafts and 360 right-side grafts. Sixteen cases developed HVOO after LDLT with an incidence rate of 2.7%, 5 with a left liver graft (2%), and 11 with a right-side graft (3%). The IR was attempted for 14 cases; among those, 8 cases were treated by stent implantation. RESULTS: The technical success rate of the initial stent implantation was 100%. The pressure gradient at the stenotic site significantly improved from 12.2 (range, 10.9-20.4 cm H2O) to 3.9 cm H2O (range, 1.4-8.2 cm H2O; P = .03). The volume of the congested graft liver decreased significantly from 1448 (range, 788-2170 mL) to 1265 mL (range, 748-1665 mL; P = .01), and the serum albumin level improved significantly from 3.3 (range, 1.7-3.7 g/dL) to 3.7 g/dL (range, 2.9-4.1 g/dL; P = .02). No procedure-related complication was noted, and the long-term stent patency was 100%. CONCLUSION: Metallic stent implantation for stenotic venous anastomosis after LDLT is a safe and effective treatment.


Assuntos
Síndrome de Budd-Chiari , Transplante de Fígado , Adulto , Humanos , Síndrome de Budd-Chiari/diagnóstico por imagem , Síndrome de Budd-Chiari/etiologia , Síndrome de Budd-Chiari/cirurgia , Transplante de Fígado/efeitos adversos , Doadores Vivos , Veias Hepáticas/diagnóstico por imagem , Veias Hepáticas/cirurgia , Resultado do Tratamento , Stents/efeitos adversos , Constrição Patológica/etiologia
13.
Magn Reson Med ; 91(5): 1863-1875, 2024 May.
Artigo em Inglês | MEDLINE | ID: mdl-38192263

RESUMO

PURPOSE: To evaluate a vendor-agnostic multiparametric mapping scheme based on 3D quantification using an interleaved Look-Locker acquisition sequence with a T2 preparation pulse (3D-QALAS) for whole-brain T1, T2, and proton density (PD) mapping. METHODS: This prospective, multi-institutional study was conducted between September 2021 and February 2022 using five different 3T systems from four prominent MRI vendors. The accuracy of this technique was evaluated using a standardized MRI system phantom. Intra-scanner repeatability and inter-vendor reproducibility of T1, T2, and PD values were evaluated in 10 healthy volunteers (6 men; mean age ± SD, 28.0 ± 5.6 y) who underwent scan-rescan sessions on each scanner (total scans = 100). To evaluate the feasibility of 3D-QALAS, nine patients with multiple sclerosis (nine women; mean age ± SD, 48.2 ± 11.5 y) underwent imaging examination on two 3T MRI systems from different manufacturers. RESULTS: Quantitative maps obtained with 3D-QALAS showed high linearity (R2 = 0.998 and 0.998 for T1 and T2, respectively) with respect to reference measurements. The mean intra-scanner coefficients of variation for each scanner and structure ranged from 0.4% to 2.6%. The mean structure-wise test-retest repeatabilities were 1.6%, 1.1%, and 0.7% for T1, T2, and PD, respectively. Overall, high inter-vendor reproducibility was observed for all parameter maps and all structure measurements, including white matter lesions in patients with multiple sclerosis. CONCLUSION: The vendor-agnostic multiparametric mapping technique 3D-QALAS provided reproducible measurements of T1, T2, and PD for human tissues within a typical physiological range using 3T scanners from four different MRI manufacturers.


Assuntos
Encéfalo , Esclerose Múltipla , Masculino , Humanos , Feminino , Reprodutibilidade dos Testes , Estudos Prospectivos , Encéfalo/diagnóstico por imagem , Imageamento por Ressonância Magnética/métodos , Imagens de Fantasmas , Esclerose Múltipla/diagnóstico por imagem , Mapeamento Encefálico
14.
Strahlenther Onkol ; 2024 Jan 05.
Artigo em Inglês | MEDLINE | ID: mdl-38180494

RESUMO

BACKGROUND: Although robot-assisted radical prostatectomy (RARP) and intensity-modulated radiotherapy are the leading respective techniques of prostatectomy and radiotherapy for localized prostate cancer, almost no study has directly compared their outcomes; none have compared mortality outcomes. METHODS: We compared 6­year outcomes of RARP (n = 500) and volumetric modulated arc therapy (VMAT, a rotational intensity-modulated radiotherapy, n = 360) in patients with cT1-4N0M0 prostate cancer. We assessed oncological outcomes, namely overall survival (OS), cancer-specific survival (CSS), radiological recurrence-free survival (rRFS), and biochemical recurrence-free survival (bRFS), using propensity score matching (PSM). We also assessed treatment-related complication outcomes of prostatectomy and radiotherapy. RESULTS: The median follow-up duration was 79 months (> 6 years). PSM generated a matched cohort of 260 patients (130 per treatment group). In the matched cohort, RARP and VMAT showed equivalent results for OS, CSS, and rRFS: both achieved excellent 6­year outcomes for OS (> 96%), CSS (> 98%), and rRFS (> 91%). VMAT had significantly longer bRFS than RARP, albeit based on different definitions of biochemical recurrence. Regarding complication outcomes, patients who underwent RARP had minimal (2.6%) severe perioperative complications and achieved excellent continence recovery (91.6 and 68.8% of the patients achieved ≤ 1 pad/day and pad-free, respectively). Patients who underwent VMAT had an acceptable rate (20.0%) of grade ≥ 2 genitourinary complications and a very low rate (4.4%) of grade ≥ 2 gastrointestinal complications. CONCLUSION: On the basis of PSM after a 6-year follow-up, RARP and VMAT showed equivalent and excellent oncological outcomes, as well as acceptable complication profiles.

15.
Can Assoc Radiol J ; : 8465371241228468, 2024 Jan 31.
Artigo em Inglês | MEDLINE | ID: mdl-38293802

RESUMO

Objective: This study aimed to investigate whether deep-learning reconstruction (DLR) improves interobserver agreement in the evaluation of honeycombing for patients with interstitial lung disease (ILD) who underwent high-resolution computed tomography (CT) compared with hybrid iterative reconstruction (HIR). Methods: In this retrospective study, 35 consecutive patients suspected of ILD who underwent CT including the chest region were included. High-resolution CT images of the unilateral lung with DLR and HIR were reconstructed for the right and left lungs. A radiologist placed regions of interest on the lung and measured standard deviation of CT attenuation (i.e., quantitative image noise). In the qualitative image analyses, 5 blinded readers assessed the presence of honeycombing and reticulation, qualitative image noise, artifacts, and overall image quality using a 5-point scale (except for artifacts which was evaluated using a 3-point scale). Results: The quantitative and qualitative image noise in DLR was remarkably reduced compared to that in HIR (P < .001). Artifacts and overall DLR quality were significantly improved compared to those of HIR (P < .001 for 4 out of 5 readers). Interobserver agreement in the evaluations of honeycombing and reticulation for DLR (0.557 [0.450-0.693] and 0.525 [0.470-0.541], respectively) were higher than those for HIR (0.321 [0.211-0.520] and 0.470 [0.354-0.533], respectively). A statistically significant difference was found for honeycombing (P = .014). Conclusions: DLR improved interobserver agreement in the evaluation of honeycombing in patients with ILD on CT compared to HIR.

16.
Radiol Case Rep ; 19(4): 1239-1242, 2024 Apr.
Artigo em Inglês | MEDLINE | ID: mdl-38292794

RESUMO

Air emboli represent rare but severe complications of computed tomography (CT)-guided lung biopsy (CTLB). No reports exist regarding the behavior of air during the early stages of air emboli. We present a case of air emboli following CTLB, evaluated by intermittent CT over a 2-hour period, spanning from onset to resolution. A man in his 60s underwent CTLB for diagnosis of a slowly enlarging pulmonary nodule in the right lower lobe. Immediately post-biopsy, chest CT revealed air emboli in the right coronary artery and apex of the ascending aorta. The patient was in the head-down position on the CT table, and intermittent CT scans were performed over a 2-hour period until the air emboli resolved. Subsequently, the patient was discharged without any complications.

17.
Neuroradiology ; 66(3): 371-387, 2024 Mar.
Artigo em Inglês | MEDLINE | ID: mdl-38236423

RESUMO

PURPOSE: To investigate the effects on tractography of artificial intelligence-based prediction of motion-probing gradients (MPGs) in diffusion-weighted imaging (DWI). METHODS: The 251 participants in this study were patients with brain tumors or epileptic seizures who underwent MRI to depict tractography. DWI was performed with 64 MPG directions and b = 0 s/mm2 images. The dataset was divided into a training set of 191 (mean age 45.7 [± 19.1] years), a validation set of 30 (mean age 41.6 [± 19.1] years), and a test set of 30 (mean age 49.6 [± 18.3] years) patients. Supervised training of a convolutional neural network was performed using b = 0 images and the first 32 axes of MPG images as the input data and the second 32 axes as the reference data. The trained model was applied to the test data, and tractography was performed using (a) input data only; (b) input plus prediction data; and (c) b = 0 images and the 64 MPG data (as a reference). RESULTS: In Q-ball imaging tractography, the average dice similarity coefficient (DSC) of the input plus prediction data was 0.715 (± 0.064), which was significantly higher than that of the input data alone (0.697 [± 0.070]) (p < 0.05). In generalized q-sampling imaging tractography, the average DSC of the input plus prediction data was 0.769 (± 0.091), which was also significantly higher than that of the input data alone (0.738 [± 0.118]) (p < 0.01). CONCLUSION: Diffusion tractography is improved by adding predicted MPG images generated by an artificial intelligence model.


Assuntos
Inteligência Artificial , Imagem de Difusão por Ressonância Magnética , Humanos , Pessoa de Meia-Idade , Adulto , Imagem de Difusão por Ressonância Magnética/métodos , Imagem de Tensor de Difusão/métodos , Imageamento por Ressonância Magnética , Redes Neurais de Computação , Processamento de Imagem Assistida por Computador/métodos
18.
Int J Comput Assist Radiol Surg ; 19(3): 581-590, 2024 Mar.
Artigo em Inglês | MEDLINE | ID: mdl-38180621

RESUMO

PURPOSE: Standardized uptake values (SUVs) derived from 18F-fluoro-2-deoxy-D-glucose positron emission tomography/computed tomography are a crucial parameter for identifying tumors or abnormalities in an organ. Moreover, exploring ways to improve the identification of tumors or abnormalities using a statistical measurement tool is important in clinical research. Therefore, we developed a fully automatic method to create a personally normalized Z-score map of the liver SUV. METHODS: The normalized Z-score map for each patient was created using the SUV mean and standard deviation estimated from blood-test-derived variables, such as alanine aminotransferase and aspartate aminotransferase, as well as other demographic information. This was performed using the least absolute shrinkage and selection operator (LASSO)-based estimation formula. We also used receiver operating characteristic (ROC) to analyze the results of people with and without hepatic tumors and compared them to the ROC curve of normal SUV. RESULTS: A total of 7757 people were selected for this study. Of these, 7744 were healthy, while 13 had abnormalities. The area under the ROC curve results indicated that the anomaly detection approach (0.91) outperformed only the maximum SUV (0.89). To build the LASSO regression, sets of covariates, including sex, weight, body mass index, blood glucose level, triglyceride, total cholesterol, γ-glutamyl transpeptidase, total protein, creatinine, insulin, albumin, and cholinesterase, were used to determine the SUV mean, whereas weight was used to determine the SUV standard deviation. CONCLUSION: The Z-score normalizes the mean and standard deviation. It is effective in ROC curve analysis and increases the clarity of the abnormality. This normalization is a key technique for effective measurement of maximum glucose consumption by tumors in the liver.


Assuntos
Fluordesoxiglucose F18 , Neoplasias , Humanos , Compostos Radiofarmacêuticos , Tomografia por Emissão de Pósitrons/métodos , Neoplasias/diagnóstico por imagem , Fígado/diagnóstico por imagem
19.
Magn Reson Med Sci ; 2024 Jan 16.
Artigo em Inglês | MEDLINE | ID: mdl-38233191

RESUMO

PURPOSE: Magnetization prepared rapid acquisition with gradient echo (MPRAGE) sequence is a gold-standard technique for voxel-based morphometry (VBM) because of high spatial resolution and excellent tissue contrast, especially between gray matter (GM) and white matter (WM). Despite its benefits, MPRAGE exhibits distinct challenge for VBM in some patients with neurological disease because of long scan time and motion artifacts. Speedily acquired localizer images may alleviate this problem. This study aimed to evaluate the feasibility of VBM using 3D Fast Low Angle Shot image captured for localizer (L3DFLASH). METHODS: Consecutive 13 patients with pathologically confirmed Alzheimer's disease (AD) (82 ± 9 years) and 21 healthy controls (HC) (79 ± 4 years) were included in this study. Whole-brain L3DFLASH and MPRAGE were captured and preprocessed using the Computational Anatomy Toolbox 12 (CAT12). Agreement with MPRAGE was evaluated for L3DFLASH using regional normalized volume for segmented brain areas. In addition to brain volume difference on VBM and Bland-Altman analysis, atrophic pattern of AD on VBM was evaluated using L3DFLASH and MPRAGE. RESULTS: Acquisition time was 18 s for L3DFLASH and 288 s for MPRAGE. There was a slight systematic difference in all regional normalized volumes from L3DFLASH and MPRAGE. For the whole cohort, GM volume measured from MPRAGE was greater than that from L3DFLASH in most of the region on VBM. When AD and HC were compared, AD-related atrophic pattern was demonstrated in both L3DFLASH and MPRAGE on VBM, although the difference was noted in significant clusters between them. CONCLUSION: Although systematic difference was noted in regional brain volume measured from L3DFLASH and MPRAGE, AD-related atrophic pattern was preserved in L3DFLASH on VBM. VBM, using speedily acquired localizer image, may provide limited but useful information for evaluating brain atrophy.

20.
Can Assoc Radiol J ; 75(1): 74-81, 2024 Feb.
Artigo em Inglês | MEDLINE | ID: mdl-37387607

RESUMO

Purpose: We investigated the effect of deep learning reconstruction (DLR) plus single-energy metal artifact reduction (SEMAR) on neck CT in patients with dental metals, comparing it with DLR and with hybrid iterative reconstruction (Hybrid IR)-SEMAR. Methods: In this retrospective study, 32 patients (25 men, 7 women; mean age: 63 ± 15 years) with dental metals underwent contrast-enhanced CT of the oral and oropharyngeal regions. Axial images were reconstructed using DLR, Hybrid IR-SEMAR, and DLR-SEMAR. In quantitative analyses, degrees of image noise and artifacts were evaluated. In one-by-one qualitative analyses, 2 radiologists evaluated metal artifacts, the depiction of structures, and noise on five-point scales. In side-by-side qualitative analyses, artifacts and overall image quality were evaluated by comparing Hybrid IR-SEMAR with DLR-SEMAR. Results: Artifacts were significantly less with DLR-SEMAR than with DLR in quantitative (P < .001) and one-by-one qualitative (P < .001) analyses, which resulted in significantly better depiction of most structures (P < .004). Artifacts in side-by-side analysis and image noise in quantitative and one-by-one qualitative analyses (P < .001) were significantly less with DLR-SEMAR than with Hybrid IR-SEMAR, resulting in significantly better overall quality of DLR-SEMAR. Conclusions: Compared with DLR and Hybrid IR-SEMAR, DLR-SEMAR provided significantly better supra hyoid neck CT images in patients with dental metals.


Assuntos
Artefatos , Aprendizado Profundo , Masculino , Humanos , Feminino , Pessoa de Meia-Idade , Idoso , Estudos Retrospectivos , Processamento de Imagem Assistida por Computador/métodos , Tomografia Computadorizada por Raios X/métodos , Algoritmos , Interpretação de Imagem Radiográfica Assistida por Computador/métodos , Doses de Radiação
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA
...